Civic Issues
Topics getting the most attention in Riverside public meetings, ranked by how frequently they are discussed.
21 issues in water utilities with high priority
Sewer Services Five-year Rate Plan through 2031
Nine years without sewer rate increases left the fund near a debt-coverage crisis. The proposed plan starts with a smaller bump in January 2027, then annual increases through 2031 to fix aging pipes, avoid spills like the $6.5 million ruptures since 2016, and fund $380 million in needed projects.
Substation transformer procurement and capital work orders
The board approved a $3.45 million project replacing aging poles, wires, and transformers on the northside to prep Circuit 26 for the faster 12kV system. Hunter Substation is 60-65% done, with commissioning in early 2027 and full cut-over by mid-2027.
Booster station power distribution improvements
The board approved $227,000 in work orders to upgrade power distribution at four water booster stations — Lemona, Cook, Mockingbird, and Jefferson — plus an $86,500 tank recoating contract at the energy center.
2027 Electric Resource Adequacy Plan
Riverside filed its annual plan showing it has enough power capacity — system, local, and flexible — to meet 2027 grid reliability requirements at the lowest cost. Staff also flagged coming CAISO rule changes that could devalue short-duration battery resources.
2025 Urban Water Management Plan
Riverside is pitching in $29,405 to update groundwater quality modeling for the Bunker Hill basin, where modeling shows salt and nitrate limits could be exceeded around 2039-2045. Early warning matters for whether a desalter or other management actions will be needed.
Membrane replacement at John W. North Water Treatment Plant
Riverside's membrane filtration plant — key to water independence — needs its 600 ultrafiltration membranes replaced for $2.1 million, a sole-source deal with ZENON/Veolia. Switching technologies would cost roughly $35 million plus a $16 million brine line, and a grant obligates the city to keep running the plant as-is.
Electric utility rate rule changes
A $148,800 consultant study will analyze how much it costs to serve each customer class and design the next five-year electric rate plan. Half of customers now have smart meters, letting the study get more granular about who uses power when.
Residential energy storage rebate program
A $5 million battery rebate — $500/kWh, up to $10,000 per household ($17,000 low-income) — could cover nearly half the cost of a typical home battery. Board members noted funds could exhaust quickly with only ~10% solar-customer adoption and asked for annual review.
2025 Urban Water Management and Water Shortage Plans
The board was scheduled to approve and recommend adoption of the annual water supply and demand assessment, a key piece of drought and supply planning.
Service Lateral Replacement Program extension
Riverside Public Utilities will keep proactively replacing aging water service laterals before they fail, through fiscal year 2028-29. Since the program began, emergency repairs have dropped sharply, saving money, reducing water loss, and shortening customer outages.
Waterman transmission main break
A July 15 leak in the main line carrying 60% of the city's water forced nine days of around-the-clock repairs 29 feet underground; parks, schools and city departments cut irrigation to keep the city in water during the heat.
Gage Canal Olivewood pipeline outage fix
Customers on Rumsey Drive and Ivy Street have been without Gage Canal water for nearly a year after the Olivewood pipeline leaked under the BNSF railroad right-of-way. The approved $97,000 lateral modifications will reroute water through the parallel Riverside Canal Pipeline as a stopgap, fully reimbursed by Gage.
Agricultural water rate report
The ag water discount rate is now officially capped at its current 245 customers because the $684,000 annual subsidy limit is expected to be reached by 2028. Dissenting board members and residents argue the cap is arbitrary, since about 12,800 properties could qualify but far fewer ever joined. The City Council can raise the cap with non-rate revenue if it chooses.
PI System software agreement with AVEVA
The $1.66 million, five-year deal keeps the software platform that runs the utility's real-time operations data — water quality dashboards, power market bidding, compliance monitoring. Staff said rejecting it would shut down daily operations and could risk compliance fines.
Public EV charger expansion
45 fast chargers are coming from Chaevi, a Korean maker now based in Riverside. Callers warned many proposed sites sit behind locked garage gates on weekends, that Ward 1 lacks working Level 2 chargers, and that the West End is being left out again.
2025 Water Shortage Contingency Plan
Riverside's playbook for how it responds when water supplies run short — drought stages, conservation triggers, and customer restrictions. The board would recommend the City Council adopt it by resolution.
Riverside Transmission Reliability Project cost reduction
An amended agreement with Southern California Edison cuts the interconnection cost by about $1.7 million, though one councilmember voted no.
Mobile-home and multi-family energy-efficiency program with SoCalGas
The Board was scheduled to consider an agreement with SoCalGas worth up to $1.6 million to fund energy-efficiency upgrades for mobile-home and multi-family residents. It would be paid from the Multi-Family Direct Install Program Account.
Backup generators for critical water infrastructure
A roughly $996,500 purchase of emergency backup generators was on the consent calendar, supporting water service reliability during outages.
TDS Management Plan Agreement with Rubidoux Community Services District
A proposed regional agreement on managing Total Dissolved Solids at the city's Regional Water Quality Control Plant. The deal shapes how Riverside and Rubidoux share responsibility for water quality — something that can affect water service and rates.
Electric grid reliability on Circuit 1313
Two work orders totaling $2.25 million were up for consideration: replacing deteriorated overhead power poles and upgrading Hunter Substation from 4kV to 12kV for Circuits 21 and 22. Both draw on the Electric Capital Account and affect long-term grid reliability.